Lotus Service Notes Section EMN
Page 18
EMN.15 - OIL TEMPERATURE SENSOR
An oil temperature sensor is mounted in the top of the VVC hydraulic control unit. The oil temperature is
used by the ECM to determine how quickly the VVC mechanism will respond to cam period change com-
mands.
To replace the sensor, unplug the electrical connector (brown), and unscrew from the hydraulic control
unit. Fit a new seal onto the sensor before inserting and tightening to 15 Nm.
Oil temperature sensor
em219a