A
Down
Limit
Switch
Up
Limit
Switch
Clear Show Position (Method 2)
① Press and hold Key in Down position to get lift to bottom limit.
② Release the Key.
③ Again, press and hold Key in the Down position.
④ Continue holding until lift starts moving up (approx. 5 sec, Key can
be released anytime after movement starts). The lift will move up for .7
seconds then stop. This indicates the Show Position is cleared.
Note that once the Show Position is cleared, the Key Switch no longer
works!
Adjustments
CAUTION: Be sure all switches are in “off” position before ad just ing limit
switch. Always be pre pared to shut lift off man u al ly when new ad just ment is
being tested. Please refer to wiring diagram.
Limit switches for the Scissor Lift SLX are preset at the factory. The “Up”
limit switch is set for fully closed. The "Down" limit switch is set for the fully
down (maintenance) position for the size lift you have ordered. The limit switch
assembly is located inside the lift and behind the Lifting Cable Drum.
Set Show Position
(can only be set if it is cleared, i.e. it cannot be re-set)
① Use Main UP/DN to get lift to desired Show Position.
② Press and hold Key in the "down" position.
③ Continue holding until lift starts moving up (approx. 5 sec, Key can be
released anytime after movement starts). The lift will move up for 2
seconds, then stop for 1 second, then go down for 1 second and stop. This
action is used to measure the amount of coast that happens near the Show
Position.
④ The coast is now calculated and the Show Position set. The lift now goes
down to the Show Position, which should be where the process started.
Clear Show Position (Method 1)
① Put the lift at the show position using the Main Down button.
② Press and hold Key in the Up position.
③ Continue holding until lift starts moving up (approx. 5 sec,
Key can be released anytime after movement starts).
The lift will move up for .75 seconds then stop. This
indicates the Show Position is cleared.
Note that once the Show Position is cleared, the Key
Switch no longer works! (See the operation above
where Show Position is not yet set.)
The Up and Down limit switches shown in the drawing are for setting the "Up
and "Fully Down." These can be adjusted manually by loosening or tightening
the screws to increase or reduce the travel.
UpDown
"Main" refers to commands sent via the wall switch or main channel
commands sent via IR or RF remote through the RP Bus.
RP/RQ Bus Ports for
remote controls such as
IR Eye, RF Receiver, LED
Wall Switch and RS232
Low Voltage Trigger
(6-24 VDC)
(Polarity Independent)
Function Indicator
KEY
WALL
RP/RQ
RP/RQ
LVT
DCU
Green
Black
Yellow
LVC-S
Pin
1 2 3 4 5 6
Y G R B
Red - Down
Black - Com
Black - Com
Blue - Up
Green
Yellow
Black
SP-KSM
Pin
1 2 3 4 5 6
Y G R B
To RS232 Port:
Yellow = Rx (Data from control system)
Green = Tx (Data to control system)
Red = Unused
Black = Gnd (Signal Ground)
Pin
1 2 3 4 5 6
Y G R B
Pin
6 5 4 3 2 1
B R G Y
220V Scissor Lift SLX by Draper page 4 of 7
www.draperinc.com
(765) 987-799
Connecting Controls
Controls plug into the data cable inputs on the Control Panel,
which is located on the Top Frame on the front side of the lift,
using RJ14 connectors.
For IR or RF Remote Control, use data cable with RJ14
connectors on both ends.
Please Note:
Data cable connections must be made using electrically
straight 4-conductor modular cable (RJ14). If making
your own cables, this means colors do not cross over:
blue leads to blue, green to green, etc. (see diagram
below).
Pin
1 2 3 4 5 6
Y G R B
Pin
1 2 3 4 5 6
Y G R B
For serial control of "Show" position, use data cable with RJ14
connectors on both ends and an R2D7 Serial Control Interface.
Plug into the "RP/RQ" input.
Please Note: If the Scissor Lift loses or is disconnected
from the power, the "Down" function will not work until
you operate the lift in the "up" direction. This allows the
lift's control encoder to recognize it's "home" location.