RP/RQ Bus Ports for
remote controls such as
IR Eye, RF Receiver, LED
Wall Switch and RS232
Low Voltage Trigger
(6-24 VDC)
Function Indicator
KEY
WALL
RP/RQ
RP/RQ
LVT
DCU
Green
Black
Yellow
LVC-S
Pin
1 2 3 4 5 6
Y G R B
Red - Down
Black - Com
Black - Com
Blue - Up
Green
Yellow
Black
KS-3
Pin
1 2 3 4 5 6
Y G R B
To RS232 Port:
Yellow = Rx (Data from control system)
Green = Tx (Data to control system)
Red = Unused
Black = Gnd (Signal Ground)
Pin
1 2 3 4 5 6
Y G R B
Pin
6 5 4 3 2 1
B R G Y
220V Scissor Lift SLX by Draper page 4 of 7
www.draperinc.com
(765) 987-799
“Show” position
Adjustment Knob
Nut must be
loosened to
enable use of the
Adjustment Knob,
then re-tightened.
Connecting Controls
Limit Adjustments
Adjustments
CAUTION: Be sure all switches are in “off” position before ad just ing limit
switch. Always be pre pared to shut lift off man u al ly when new ad just ment is
being tested. Please refer to wiring diagram.
Limit switches for the Scissor Lift SLX are preset at the factory. The “Up”
(closed) limit switch is set for fully closed. The “down” (show) limit switch is set
for "Show" position for the size lift you have ordered. The limit switch assembly
is located inside the lift and behind the Lifting Cable Drum.
Adjusting “Down” (show) position—“Down” position may be ad just ed by
Turning the Limit Switch Adjustment Knob.
Adjusting “Up” (closed) position—Because the “up” (closed) position is
preset at the factory, Draper does not recommend changing this position
using the limit switch. The “up” position of the closure may be changed by
changing the length of threaded rod used to attach the closure (see closure
instruction section).
Caution: Do not adjust the threaded rods so that the motor is still
running after the lift is closed. This could result in damage to the motor.
Controls plug into the data cable inputs on the Control Panel,
which is located on the Top Frame on the front side of the lift,
using RJ14 connectors.
For IR or RF Remote Control, use data cable with RJ14
connectors on both ends.
Please Note:
Data cable connections must be made using electrically straight 4-conductor
modular cable (RJ14). If making your own cables, this means colors do not cross
over: blue leads to blue, green to green, etc. (see diagram below).
Please Note: When adjusting
the limit switch, make sure
the bracket engages the
outside edge of the snap
switch.
Bracket
Snap Switch
Pin
1 2 3 4 5 6
Y G R B
Pin
1 2 3 4 5 6
Y G R B
For serial control of "Show" position, use data cable with RJ14
connectors on both ends and an R2D7 Serial Control Interface.
Plug into the "RP/RQ" input.