RS232 to RTS Interface
with X10 Compatibility
®
Description
The RS232 to RTS Interface is a 16-channel RTS transmitter that enables third party home automa-
tion systems to directly control Somfy’s line of RTS motors and controls. The interface also includes
X10 compatibility for direct control of RTS product from an X10 powerline system. The interface plugs
into a standard 115 VAC electrical outlet.
Part Number 1810686
Operating Procedures
RTS Channel Programming
Ensure the RTS motor or receiver to be controlled has already been assigned to a channel on a Telis or similar channel as outlined in the
specifi c product instructions. All limits, intermediate positions and programmable functions should be set.
Set the RTS receiver or motor into its programming mode as outlined in the specifi c product instructions.
Set the Rotary Address Dial to the channel you want the motor or receiver to respond to. Press the Programming Button on the Interface.
The motor or receiver will respond accordingly.
RS232 Operation
Set RS232 communication settings to: 9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity
Use the ASCII protocol: <!> <2 digit unit code> <Directional Command>
The directional commands must be capital letters and are as follows:
U: up
D: down
S: stop
There must be a 500mS delay between successive commands.
Examples: Motor 2 Up: !02U
Motor 5 Down: !05D
Motor 1 Stop: !01S
X10 Operation
Set the Rotary Address Dial to the desired X10 house code.
Send the address then the following commands to activate
that motor or receiver:
BRIGHT: UP
DIM: DOWN
OFF: STOP
Examples: Motor 1 Up: 1 Bright
Motor 3 Down: 3 Dim
Motor 5 Stop: 5 Off