Draper SC1 Manual de instrucciones Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
10 Motor Power Panel
®
The 10 motor power panel is for powering the Low Voltage Radio Motor. It is not required, but it does make installation easier.
A transformer is still needed, and it will feed power to the panel. You can parallel wire the motors directly into the power feed off the trans-
former. This, however, makes connecting and disconnecting the motor from power to program it diffi cult and cumbersome. With a power panel
you can disconnect or connect each motor individually for programming, this will make installation quicker.
A power panel is also set-up to work with wiring that might have been pulled for a different system.
The diagram below shows the panel and how motors plug into it.
12/24V DC
Input
Po we r
LED’s
+
_
2A Fuse
7
6
5
4
3
2
1
22 Gauge/2 conductor
150 Ft. Maximum
Power Supply Input
Connect motor to
terminals 5 & 6 of
motor connector
Connect motor
connector to
power panel
Sonesse 30 Motor
18 Gauge/2 Conductor
5 Ft. Maximum
Sonesse 30 Motor
Page 29 of 120
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 119 120

Comentarios a estos manuales

Sin comentarios