Installation Instructions
™
R2D7 RS232 Professional Integration Interface by Draper
Copyright ©2004 Draper Inc. Form IntelliFlex-RS232_Inst04 Printed in U.S.A.
If you encounter any diffi culties installing/wiring your IntelliFlex
RS232 Professional Integration Interface, call your dealer or
Draper, Inc., Spiceland, Ind., (765) 987-7999; fax (765) 987-7142;
To Bus System 7 (or to RF Transmitter)
To Bus System 6
To Bus System 5
To Bus System 4
To RS232 Port:
Yellow = Rx (Receive data from control system)
Green = Tx (Transmit data to control system)
Red = Unused
Black = Gnd (Signal Ground)
To Bus System 1
To Bus System 2
To Bus System 3
Serial Port to Motor Link
Information Data Number of characters
1
Header (Start of command) * (asterisk) for use on RP B US 1
Subsystem number or
Administration command
0
2
– 7 if BUS, 7 – 99 if Radio
V
3
= report version
R = make port 7 Radio
4
B = make port 7 BUS
1 or 2
Command
5
o = open c = close s = stop
p = program q
6
= quit sending
1
Channel
7
00
8
–60
9
2
Time to send
10 11
0 0 0
12
– 9 9 9 20
th
of seconds
13
(this value is optional) 3
Terminator ; (semicolon) or “ CR” (enter key) 1
Pause Send a command on an unused channel for the desired pause
time.
Motor Link to Serial Port
Event R2D7 sends
Powered up “ version, X -on”
Terminator is received
“ LF” if good command
“U” sent if command cannot be understood
“ CR” is sent after command has been relayed to motors
Buffer
14
overflows and all data is purged “O” is sent
Buffer is half full “X -off ” (Ctrl -S)
Buffer is empty “X -on” (Ctrl -Q), but only if X -off was previously sent
Special characters
Character Description
ASCII Character Number
“ ; ” Semicolon, signifies end of command 59 (0x3B)
“ CR ” Carriage return, signifies end of command 13 (0x0D)
“ * ” Asterisk, Shift 8 on most keyboards 42 (0x2A)
“ LF ” Line feed, ignored (not used) 10 (0x0A)
“ X -off ” Ctrl -S on most keyboards, requests sender to stop sending 19 (0x13)
“ X -on ” Ctrl -Q on most keyboards, requests sender to resume sending 17 (0x11)
1. Total message length may be as short as 2 and as long as 10 characters, typically 6.
2. 0 means ALL systems, for super groups ALL does not include the radio channels.
3. Version reports “2.1” then R if administered as Radio, or B if BUS, followed by carriage return (All characters after V in this command are ignored).
4. Radio requires a RF TM be plugged into port 7 jack.
5. Case is important: o is different from O and so on.
6. Stop sending a forever command. Any other command will stop transmission, but an error will be reported.
7. If command is stop or quit, then this value is optional and ignored.
8. 00 = ALL.
9. 60 = “cut strap ALL” (note that version 2.0 used 25 for this channel).
10. If no digits, then the command is sent for 2 seconds, except for stop and program which are sent for ¼ second.
11. Time between commands = .5 sec if multiple commands are buffered (Time = .1 sec after a stop).
12. 000 = Forever, use the q command to stop transmission.
13. Max timed pulse = 50 sec. If this is a radio command, the value is rounded up to the nearest 10th second.
14. Buffer is 120 bytes long.
Please Note
➀
Includes free “GUI” software capable of scheduling timed events and
global alignment positioning of shades.
➁
For information on programming and operation, see IntelliFlex
Programmer instructions available at www.draperinc.com.
➂
This input device can be used with SC1, SGC4 or SPGC4.
Serial Port Adapter
Converts a standard DB9 serial output of
a PC into an RJ11 connection providing
RS232 serial commands.
USB-to-DB9 Serial Port Converter
Serves as a bridge between USB port and
standard RS232 Serial Port.
You may also need ...